    The WXS has portlets on the Dashboard screen.

    A portlet is a small display that shows one piece of information with a reset button. An example of a portlet would be “Total Jams” or “Current Lane Full” conditions.

     

     

    When the WXS user configures new portlets, they are required to list two PLC tags: one Read tag and one Write tag. The Read tag is usually the .ACC value of a Counter and the write tag is always a BOOL that is used to reset the counter.

     

     

    The standard logic would be to increment the counter every time the “event” the WXS is tracking/displaying happens. It continues to do so until a 1 (True) is written to the Write tag (reset) BOOL; at which point will reset the counter and then continue counting.